18 research outputs found

    Small bowel Crohn’s disease: MR enteroclysis and capsule endoscopy compared to balloon-assisted enteroscopy

    Get PDF
    New modalities are available to visualize the small bowel in patients with Crohn’s disease (CD). The aim of this study was to compare the diagnostic yield of magnetic resonance enteroclysis (MRE) and capsule endoscopy (CE) to balloon-assisted enteroscopy (BAE) in patients with suspected or established CD of the small bowel. Consecutive, consenting patients first underwent MRE followed by CE and BAE. Patients with high-grade stenosis at MRE did not undergo CE. Reference standard for small bowel CD activity was a combination of BAE and an expert panel consensus diagnosis. Analysis included 38 patients, 27 (71%) females, mean age 36 (20–74) years, with suspected (n = 20) or established (n = 18) small bowel CD: 16 (42%) were diagnosed with active CD, and 13 (34%) by MRE with suspected high-grade stenosis, who consequently did not undergo CE. The reference standard defined high-grade stenosis in 10 (26%) patients. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value of MRE and CE for small bowel CD activity were 73 and 57%, 90 and 89%, 88 and 67%, and 78 and 84%, respectively. CE was complicated by capsule retention in one patient. MRE has a higher sensitivity and PPV than CE in small bowel CD. The use of CE is considerably limited by the high prevalence of stenotic lesions in these patients

    Small bowel enteroclysis with magnetic resonance imaging and computed tomography in patients with failed and uncertain passage of a patency capsule

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Video capsule enteroscopy (VCE) has revolutionized small bowel imaging, enabling visual examination of the mucosa of the entire small bowel, while MR enteroclysis (MRE) and CT enteroclysis (CTE) have largely replaced conventional barium enteroclysis. A new indication for MRE and CTE is the clinical suspicion of small bowel strictures, as indicated by delayed or non-delivery of a test capsule given before a VCE examination, to exclude stenosis. The aim of this study was to determine the clinical value of subsequent MRE and CTE in patients in whom a test capsule did not present itself in due time.</p> <p>Methods</p> <p>Seventy-five consecutive patients were identified with a delayed or unnoticed delivery of the test capsule. Seventy patients consented to participate and underwent MRE (44) or CTE (26). The medical records and imaging studies were retrospectively reviewed and symptoms, laboratory results and imaging findings recorded.</p> <p>Results</p> <p>Lesions compatible with Crohns disease were shown by MRE in 5 patients, by CTE in one and by VCE in four, one of whom had lesions on MRE. In patients without alarm symptoms and findings (weight loss, haematochezia, anaemia, nocturnal diarrheoa, ileus, fistula, abscess and abnormal blood tests) imaging studies did not unveil any such lesion. VCE's were performed in only 20 patients, mainly younger than 50 years of age, although no stenotic lesion was shown by MRE and CTE. In the remaining 50 patients no VCE or other endoscopic intervention was performed indicating that the referring physician was content with the diagnostic information from MRE or CTE.</p> <p>Conclusion</p> <p>The diagnostic value of MRE and CTE is sufficient for clinical management of most patients with suspected small bowel disease, and thus VCE may be omitted or at least postponed for later usage.</p

    Frequency and Nature of Incidental Extra-Enteric Lesions Found on Magnetic Resonance Enterography (MR-E) in Patients with Inflammatory Bowel Diseases (IBD)

    Get PDF
    The aim of this study was to determine the occurrence of extra-enteric findings in a large cohort of patients undergoing magnetic resonance enterography (MR-E) and to classify the clinical significance of these findings.We retrospectively analyzed 1154 MR-E performed in 1006 patients referred to our radiological department between 1999-2005. The reasons for referral were suspected or proven inflammatory bowel diseases (IBD) (n = 710), further diagnostic work-up for small bowel disease because of non-specific abdominal symptoms (SBD; n = 182) or suspected small bowel malignancies (SBM; n = 114). All extra-enteric findings were reviewed by a radiologist and a gastroenterologist and were classified as having high, moderate, or low significance for further diagnostic or therapeutic procedures.The average age of all patients was 40+/-16 (Mean+/-SD) years (y) (IBD 35+/-13 y; SBD 49+/-16 y; SBM 57+/-15 y). A total of 1113 extra-enteric findings were detected in 600 of 1006 patients (59.6%). Of these findings 180 (16.2%) were judged as having a high, 212 (19.0%) a moderate and 721 (64.8%) a low significance. On a per group basis in patients with IBD 12.0% of the findings were of major clinical significance compared to 13.7% and 33.3% in patients with SBD and SBM, respectively. The most common major findings were abscesses (69.9%) in the IBD group and extraintestinal tumors, metastases or masses in the SBD and SBM groups (41.9% and 74.2%, respectively).MR-E reveals a substantial number of extra-enteric findings, supporting the role of a cross-sectional imaging method for the evaluation of the small bowel

    MR enteroclysis of inflammatory small-bowel diseases

    No full text
    OBJECTIVE: MR enteroclysis has been introduced in the workup of small-bowel diseases. The major advantage of this technique over others is the combined visualization of luminal, mural, and extramural abnormalities. In this article we propose an MR enteroclysis protocol, present a stepwise approach for evaluation of these examinations, and discuss the different inflammatory conditions that can be detected. CONCLUSION: MR enteroclysis can be considered the current first-line imaging technique for inflammatory small-bowel disorder

    Comparison of magnetic resonance enteroclysis and capsule endoscopy with balloon-assisted enteroscopy in patients with obscure gastrointestinal bleeding

    No full text
    Background and study aims: New modalities are available for visualization of the small bowel in patients with possible obscure gastrointestinal bleeding (OGIB), but their performance requires further comparison. This study compared the diagnostic yield of magnetic resonance enteroclysis (MRE) and capsule endoscopy in patients with OGIB, using balloon-assisted enteroscopy (BAE) as the reference standard. Patients and methods: Consecutive consenting patients who were referred for evaluation of OGIB were prospectively included. Patients underwent MRE followed by capsule endoscopy and BAE. Patients with high grade stenosis at MRE did not undergo capsule endoscopy. The reference standard was BAE findings in visualized small-bowel segments and expert panel consensus for segments not visualized during BAE. Results: Over a period of 26 months, 38 patients were included (20 female [53 %]; mean age 58 years, range 28-75 years). Four patients (11 %) did not undergo capsule endoscopy due to high grade small-bowel stenosis at MRE (n=3; 8%) or timing issues (n=1; 3%). Capsule endoscopy was non-diagnostic in one patient. The reference standard identified abnormal findings in 20 patients (53 %). MRE had sensitivity, specificity, and positive and negative likelihood ratios of 21%, 100%, infinity, and 0.79, Conclusion: Capsule endoscopy performed better than MRE in the detection of small-bowel abnormality in patients with OGIB. MRE may be considered as an alternative for the initial examination in patients with clinical suspicion of small-bowel stenosis
    corecore